310C14
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 100mV/g
Measurement range: ±50g pk
Frequency range (±5%): 1-6k Hz
Frequency range (±10%): 0.5-8k Hz
Operating temperature: -54~121 ℃The company focuses on the core technology of vibration sensors and provides industry vibration testing and detection solutions.
Keywords:
Category:
Product description
Product Data Indicators
| Model | Imperial Units | International System of Units | Note | |
| Performance Indicators | ||||
| Sensitivity (±10%) | 100 mV/g | 10.2 mV/(m/s 2) | ||
| Measurement Range | ±50g pk | ±490 m/s 2 pk | ||
| Resolution | 0.0001g rms | 0.001m/s2 rms | ||
| Nonlinearity | ≤1% | ≤1% | [3] | |
| Frequency Range | ±5%(Hz) ±10%(Hz) |
1-6k 0.5-8k |
1-6k 0.5-8k |
[2] |
| Resonant Frequency | >26 kHz | >26 kHz | [1] | |
| Time Constant (s) | ≤1 s | ≤1 s | ||
| Transverse Sensitivity | ≤5% | ≤5% | ||
| Electrical Characteristics | ||||
| Supply Voltage | 18-28 VDC | 18-28 VDC | [4] | |
| Supply Current | 2-10 mA | 2-10 mA | [5] | |
| Output Impedance | ≤100 Ω | ≤100 Ω | ||
| Bias Voltage | 11±1.5 V | 11±1.5 V | [1] | |
| Spectrum Noise | 10Hz 100Hz 1000Hz |
10 μg/ √Hz 3 μg/√Hz 2 μg/√Hz |
10 μg/ √Hz 3 μg/√Hz 2 μg/√Hz |
|
| Installation Insulation Resistance (Ω) | — | |||
| Environmental Characteristics | ||||
| Limit Acceleration Value (g peak) | ±500 g pk | ±4,900 m/s 2 pk | ||
| Limit Shock Value (g peak) | ±1,000 g pk | ±9,800 m/s 2 pk | ||
| Temperature Range | -65~250 ℉ | -54~121 ℃ | ||
| Sensitivity Temperature Coefficient | 0.2 %/℃ | 0.2 %/℃ | ||
| Physical Characteristics | ||||
| Sealing Type | IP68 | IP68 | ||
| Sensing Element | Piezoelectric Ceramic | Piezoelectric Ceramic | ||
| Housing Material | Stainless Steel | Stainless Steel | ||
| Output Connector | Waterproof Integral Cable | Waterproof Integral Cable | ||
| Dimensions | Φ 0.58× 1.08(in) | Φ 14.8×27.5(mm) | ||
| Mounting Method | M5 | M5 | ||
| Weight | 0.55 oz | 15.5 g | [1] | |
| Does it support customized TEDS? | No | No | ||
Note:
[1] Inherent characteristics
[2] Low-frequency response is addressed by external signal conditioning.
[3] Least squares method
[4] Two-wire constant current excitation power supply, recommended voltage 24V
[5] Recommended excitation working current 4mA
Product Message
If you are interested in our products, please leave your contact information, and we will contact you as soon as possible