366A21
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 10mV/g
Measurement range: ±500g pk
Frequency range (±5%): 0.5-10k Hz
Frequency range (±10%): 0.3-13k Hz
Operating temperature: -54~121 ℃The company focuses on the core technology of vibration sensors and provides industry vibration testing and detection solutions.
Keywords:
Category:
Product description
Product Data Metrics
| Model | Imperial Units | International System of Units | Note | |
| Performance Indicators | ||||
| Sensitivity (±10%) | 10mV/g | 1.02 mV/(m/s 2) | ||
| Measurement Range | ±500g pk | ±4,900 m/s 2 pk | ||
| Resolution | 0.001g rms | 0.01m/s2 rms | ||
| Nonlinearity | ≤1% | ≤1% | [3] | |
| Frequency Range | ±5%(Hz) ±10%(Hz) |
0.5-10k 0.3-13k |
0.5-10k 0.3-13k |
[2] |
| Resonant Frequency | >65 kHz | >65 kHz | [1] | |
| Time Constant (s) | ≤1 s | ≤1 s | ||
| Transverse Sensitivity | ≤5% | ≤5% | ||
| Electrical Characteristics | ||||
| Supply Voltage | 18-28 VDC | 18-28 VDC | [4] | |
| Supply Current | 2-10 mA | 2-10 mA | [5] | |
| Output Impedance | ≤100 Ω | ≤100 Ω | ||
| Bias Voltage | 11±1.5 V | 11±1.5 V | [1] | |
| Spectrum Noise | 10Hz 100Hz 1000Hz |
105 μg/ √Hz 30 μg/√Hz 22 μg/√Hz |
105 μg/ √Hz 30 μg/√Hz 22 μg/√Hz |
|
| Installation Insulation Resistance ( Ω ) | — | |||
| Environmental Characteristics | ||||
| Limit Acceleration Value (g peak) | ±2,500 g pk | ±24,500 m/s 2 pk | ||
| Limit Shock Value (g peak) | ±5,000 g pk | ±49,000 m/s 2 pk | ||
| Temperature Range | -65~250 ℉ | -54~121 ℃ | ||
| Sensitivity Temperature Coefficient | 0.2 %/℃ | 0.2 %/℃ | ||
| Physical Characteristics | ||||
| Sealing Type | Laser Welding | Laser Welding | ||
| Sensing Element | Piezoelectric Ceramic | Piezoelectric Ceramic | ||
| Housing Material | Titanium | Titanium | ||
| Output Connector | 8-36 four-pin/1/4-28 four-pin | 8-36 four-pin/1/4-28 four-pin | ||
| Dimensions | 0.35 Cube (in) | 9 Cube (mm) | ||
| Mounting Method | M2.5 screw hole | M2.5 screw hole | ||
| Weight | 0.10 oz | 2.8 g | [1] | |
| Does it support customized TEDS? | No | No | ||
Note:
[1] Inherent characteristics
[2] Low-frequency response is addressed by external signal conditioners
[3] Least squares method
[4] Two-wire constant current excitation power supply, recommended voltage 24V
[5] Recommended excitation working current 4mA
Product Message