Screen
Selected
310D01
Piezoelectric charge output type (PE) accelerometer
Sensitivity (±10%): 5 pC/g
Measurement range: ±6,000 g pk
Frequency range (±5%): 15k Hz
Frequency range (±10%): 16k Hz
Operating temperature: -55~+260℃
量程:1-10
347D03
Piezoelectric charge output type (PE) accelerometer
Sensitivity (±10%): 50 pC/g
Measurement range: ±300 g pk
Frequency range (±5%): 3k Hz
Frequency range (±10%): 4k Hz
Operating temperature: -55~+500℃
量程:11~100
347D02
Piezoelectric charge output type (PE) accelerometer
Sensitivity (±10%): 10 pC/g
Measurement range: ±800 g pk
Frequency range (±5%): 4k Hz
Frequency range (±10%): 5k Hz
Operating temperature: -55~+500℃
量程:1-10
347D01
Piezoelectric charge output type (PE) accelerometer
Sensitivity (±10%): 5 pC/g
Measurement range: ±1,000 g pk
Frequency range (±5%): 4k Hz
Frequency range (±10%): 5k Hz
Operating temperature: -55~+500℃
量程:1-10
340D02
Piezoelectric charge output type (PE) accelerometer
Sensitivity (±10%): 50 pC/g
Measurement range: ±300 g pk
Frequency range (±5%): 3k Hz
Frequency range (±10%): 5k Hz
Operating temperature: -55~+500℃
量程:11~100
310G39
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 1000 mV/g
Measurement range: ±10 g pk
Frequency range (±5%): 1-3k Hz
Frequency range (±10%): 0.5-4k Hz
Operating temperature: -54~121 ℃
310G49
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 1000 mV/g
Measurement range: ±5 g pk
Frequency range (±5%): 1-3k Hz
Frequency range (±10%): 0.5-4k Hz
Operating temperature: -54~121 ℃
340D01
Piezoelectric charge output type (PE) accelerometer
Sensitivity (±10%): 10 pC/g
Measurement range: ±800 g pk
Frequency range (±5%): 4k Hz
Frequency range (±10%): 6k Hz
Operating temperature: -55~+500℃
量程:1-10
316C14
Piezoelectric voltage output type (IEPE) accelerometer Sensitivity (±10%): 100 mV/g Measurement range: ±50 g pk Frequency range (±5%): 1-8k Hz Frequency range (±10%): 0.5-10k Hz Operating temperature: -54~121 ℃
316C12
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 20 mV/g
Measurement range: ±250 g pk
Frequency range (±5%): 1-9k Hz
Frequency range (±10%): 0.5-10k Hz
Operating temperature: -54~121 ℃
316C13
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 50 mV/g
Measurement range: ±100 g pk
Frequency range (±5%): 1-8k Hz
Frequency range (±10%): 0.5-10k Hz
Operating temperature: -54~121 ℃
316C11
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 10 mV/g
Measurement range: ±500 g pk
Frequency range (±5%): 1-9k Hz
Frequency range (±10%): 0.5-10k Hz
Operating temperature: -54~121 ℃
310G38
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 500 mV/g
Measurement range: ±10 g pk
Frequency range (±5%): 1-4k Hz
Frequency range (±10%): 0.5-5k Hz
Operating temperature: -54~121 ℃
310G31
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 1000 mV/g
Measurement range: ±5 g pk
Frequency range (±5%): 1-3k Hz
Frequency range (±10%): 0.5-4k Hz
Operating temperature: -54~121 ℃
310G48
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 500 mV/g
Measurement range: ±10 g pk
Frequency range (±5%): 1-4k Hz
Frequency range (±10%): 0.5-5k Hz
Operating temperature: -54~121 ℃
310G45
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 100 mV/g
Measurement range: ±50 g pk
Frequency range (±5%): 1-5k Hz
Frequency range (±10%): 0.5-6k Hz
Operating temperature: -54~121 ℃
310G41
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 10 mV/g
Measurement range: ±500 g pk
Frequency range (±5%): 1-8k Hz
Frequency range (±10%): 0.5-10k Hz
Operating temperature: -54~121 ℃
337H15
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 5 V/g
Measurement range: ±1 g pk
Frequency range (±5%): 0.5-300k Hz
Frequency range (±10%): 0.3-500k Hz
Operating temperature: -54~121 ℃
337H12
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 2 V/g
Measurement range: ±2.5 g pk
Frequency range (±5%): 0.5-300k Hz
Frequency range (±10%): 0.3-500k Hz
Operating temperature: -54~121 ℃
336H12
Piezoelectric voltage output type (IEPE) accelerometer
Sensitivity (±10%): 1 V/g
Measurement range: ±5 g pk
Frequency range (±5%): 0.5-4k Hz
Frequency range (±10%): 0.2-5k Hz
Operating temperature: -54~121 ℃